Spa Operators Guide
48
GENERAL XM OVERLAY
DIAGNOSTIC MESSAGE
The high limit circuit is tripped. Usually, the kinetic heating
protection or the current monitoring circuity will shut down the
heater before the error can occur.
Add cold water to spa and let heater cool down. Reset spa pack
using current breaker.
Temperature probe defective.
This error clears itself when the error condition is no longer present.
Reset the breaker if the error is still there replace the In.therm
The ID number of the in.therm vs the InXm is wrong (CE/UL)
There is a CE In.Therm connected to a UL In.Xm or vice versa.
Change he In.Therm or In.Xm to the appropriate version.
For all the above, the system has not detected a current change
when turning on or off the device.
Make sure the device is correctly connected (plug is sealed). If
possible, manually change the output status (on/off) of the device
and cycle through all possible states (i.e low and high speeds). Reset
spa pack. If error does not clear, problem is probably with the device,
it will need to be serviced.
This is not an error message
A solid Sc means the system is scanning all the output to learn the
current draw of every accessory connected.
A scan error was detected
Every time a low-level option is changed, the system must “learn” the
currents associated to each output/load. During this learning process,
the device(s) connected to OUT8 (direct output, no relay) must be
disconnected (or off). If, not the system will report this code. Once the
load is correctly disconnected, the breaker has to be reset than the
user needs to restart the learning process by selecting the low level
configuration and set the breaker Once the learning if finished, the
accessories connected to OUT8 may be reconnected.
This is not an error message
The breaker size selected is lower than the total current of each
output. The In.Xm will manage the current accordingly.