Spa Operators Guide
47
GENERAL XM OVERLAY
DIAGNOSTIC MESSAGE
A hardware error was detected in the in.xm pack
Reset the spa back by shutting the breaker off then on again, manually
change the status of all the pumps and accessories. If the problem
still persists, replace in.xm pack.
The InXm’s internal temperature is too high
Remove spa skirt and let system cool down. A system reset may be
required to clear error.
The Input voltage is too low
Was this error present since 1st power-up of the in.xm? If so, check
the input terminal connections to make sure they are correctly wired
and tight. Otherwise have a certified electrical verify the power line
quality.
Fuse #1 is blown
Replace the blown fuse with an identically rated fuse.
Fuse #2 is blown
Replace the blown fuse with an identically rated fuse.
Fuse #3 is blown
Replace the blown fuse with an identically rated fuse.
A hardware error was detected in the in.therm.
Restart the spa pack; make sure the heater restarts by changing the
set point. If problem still persists, replace in.therm
The error occurs if the in.therm is trying to heat water, but does
not detect any temperature rise.
Make sure the in.therm power cord is correctly inserted and sealed in
the in.xm. Restart the system. The system will preform a flow check. If
the error code appears before any temperature as displayed, replace
in the in.therm.
Occurs when a “no flo” condition is detected by the in.therm.
Make sure that the pump associated to the heater (pump #1 or
Circulation Pump is running. Check and clean filters. Make sure
water valves are open. Make sure there is no air lock condition ( or
any object obstructs passage of water within the in.therm).
This code occurs when a communications problem exists
between the in.xm and in.therm.
Make sure remoter heater cable is correctly connected,; then reset
system. If condition persists, visually verify male connector pins to
make sure they are not bent. If the above does not solve problem,
either in.xm or in.therm may need to be replaced.